Higher-capacity oil-cooled voltage regulation up to 139 A per phase for heavy manufacturing plants and CNC machine lines.

Heavy-Duty Automatic Voltage Regulation for Industrial Power Systems
The Voltkon 20 kVA Air Cooled Servo Stabilizer is designed for industrial and commercial electrical systems where significant voltage fluctuations can affect machinery, production equipment, and critical electrical loads. Its servo-controlled voltage regulation system continuously monitors the incoming supply and automatically corrects voltage variations to maintain a stable, controlled output.
Voltage fluctuations can cause equipment overheating, nuisance tripping, inconsistent machine operation, reduced performance, and severe electrical stress on critical components. A 20 kVA air cooled servo stabilizer continuously senses incoming voltage variations and adjusts the correction mechanism automatically.
Incoming utility line experiencing sags, surges, or phase imbalance enters the stabilizer.
Microprocessor control circuit samples incoming voltage continuously in real time against nominal reference.
High-torque AC synchronous servo motor rotates the silver-plated carbon brush on the variable autotransformer.
Series buck-boost transformer injects or subtracts exact compensatory voltage in phase with the load line.
Delivers pure sinusoidal 415V/400V ±1% power with zero waveform distortion to your industrial equipment.
⚙️ Engineering Customization: The actual input correction range, output voltage, regulation accuracy, and protection arrangement are engineered to match your site's specific electrical conditions.
Engineered with heavy-duty components for demanding industrial environments and continuous uptime.
Designed to handle heavy multi-machine industrial loads up to 28.8 A (400V) or 83.5 A (415V) per phase.
Transformer assembly submerged in dielectric transformer oil for superior heat dissipation and electrical insulation.
Closed-loop solid-state electronic control maintains an exact output within ±1% of the nominal voltage setpoint.
High-torque AC synchronous servo drive delivers swift, smooth, stepless correction with zero hunting or overshoot.
Microprocessor continuously samples incoming mains voltage to instantly initiate correction before downstream issues occur.
Heavy-duty series buck-boost transformer handles primary power transfer, minimizing electrical wear on the dimmer.
Engineered to power inductive, resistive, capacitive, and high-harmonic non-linear electronic loads seamlessly.
Standard 3-Phase 4-Wire with independent phase correction or custom high-current single-phase architecture.
99.9% pure electrolytic copper coils ensure minimal $I^2R$ electrical losses, higher efficiency, and superior thermal withstand.
Built with prime-grade, low-loss CRGO silicon steel laminations for maximum magnetic flux density and minimal idle losses.
Integrated digital LED/LCD display for input voltage, output voltage, individual phase current, and operating status.
Equipped with industrial MCCB/MCB protection and electronic current-sensing trip circuits to protect connected loads.
Automatic cutoff with time delay relay safely disconnects output when voltage exceeds extreme pre-set safety thresholds.
Manual rotary bypass switch or motorized bypass contactor allows routine servicing without plant shutdown.
Heavy-gauge MS steel tank with 7-tank anti-corrosion chemical treatment, epoxy powder coating, and leak-proof seals.
Tailored input ranges (340V-470V standard, 300V-480V wide, 250V-480V ultra-wide) engineered to local feeder measurements.
Factory calibrated to 415V, 400V, 380V (for imported European/Asian machinery), or 230V single phase as required.
Engineered for 100% continuous full-load operation on demanding factory floors with heavy thermal withstand.
The 6-step electro-mechanical closed loop process delivering precision output regulation.
The solid-state electronic control circuit continuously monitors incoming supply voltage across all three phases in real time.
The measured voltage is compared against the pre-set reference voltage (e.g. 415V / 400V) to calculate exact error magnitude and polarity.
When input voltage deviates, the servo motor rotates the silver-alloy carbon roller brush across the toroidal variable transformer.
The primary winding of the series buck-boost transformer receives the variable voltage and adds (boosts) or subtracts (bucks) the differential voltage in series with the mains.
The active transformer assembly is immersed in high-grade dielectric insulating oil, which absorbs heat and dissipates it via natural convection through tank cooling fins.
The corrected, distortion-free pure AC power is delivered smoothly to connected industrial machines, protecting sensitive components and ensuring peak output.
Proven power conditioning protection across heavy manufacturing, automation, motor drives, and infrastructure.
⚠️ Motor & High-Inrush Sizing Advisory: Motor starting and high-inrush loads should be evaluated carefully before final stabilizer sizing. Starting currents (often 5x to 7x rated running current for Direct-On-Line motors) require appropriate capacity headroom.
Standard engineering parameters and customizable build options.
To calculate the nominal full-load current for a three-phase and single-phase electrical installation:
• At 400V 3-Phase: 60,000 / (1.732 × 400) ≈ 28.8 Amperes
• At 415V 3-Phase: 60,000 / (1.732 × 415) ≈ 27.8 Amperes
• At 230V 1-Phase: 60,000 / 230 ≈ 87.0 Amperes
• At 240V 1-Phase: 60,000 / 240 ≈ 250.0 Amperes
Important: These are nominal apparent-power currents. Actual permissible loading should consider power factor, load characteristics, starting/inrush current, ambient conditions, and the stabilizer's design.
Oil cooling provides distinct advantages where transformer assemblies require robust heat transfer and heavy-duty insulation.
Insulating oil circulates naturally around windings, transferring internal core heat directly to the radiator tank surfaces for efficient ambient dissipation.
Transformer oil delivers exceptional dielectric breakdown strength, insulating active conductors and preventing internal corona discharge or tracking.
Oil-cooled units are housed in rugged hermetically sealed or conservator steel tanks, shielding active electrical parts from airborne dust, moisture, and chemical fumes.
A properly maintained oil-cooled system supports round-the-clock continuous manufacturing operation with outstanding thermal margins and long lifespan.
The appropriate input range should be selected from actual site grid measurements rather than assumed generic values.
The lowest line voltage recorded during peak grid demand or local heavy industrial starting events.
The highest line voltage recorded during midnight/off-peak periods when industrial feeders are lightly loaded.
The nominal steady-state supply voltage present under normal plant operating conditions.
Voltage sags caused by nearby heavy loads such as induction furnaces, large presses, or welders on the same feeder.
Engineering Rule: A wide correction range should not be assumed simply because the stabilizer is rated at 20 kVA. Sizing a wider range than necessary increases autotransformer size and footprint; the range should be engineered according to actual site voltage data.
Compare cooling topologies to choose the optimal configuration for your plant floor or commercial building.
| Feature / Parameter | 20 kVA Oil Cooled Stabilizer | 20 kVA Air Cooled Stabilizer |
|---|---|---|
| Cooling Medium | Mineral Transformer Oil (ONAN) | Natural / Forced Air with Cooling Fans |
| Thermal Management | Oil-assisted continuous heat transfer | Air-based forced convection heat transfer |
| Oil Maintenance | Required (Periodic level & BDV inspection) | Not applicable (Zero oil handling) |
| Construction & Tank | Hermetic/Conservator oil tank enclosure | Ventilated sheet steel IP21/IP31 louvred cabinet |
| Industrial Duty | High-duty heavy continuous industrial plants | Indoor commercial, clean rooms & light industry |
| Installation Environment | Outdoor / Indoor (with oil safety provisions) | Indoor clean environment with adequate airflow |
| Typical Suitability | Harsh plant floors, dust, heavy machinery | Commercial buildings, hospitals, server rooms |
Selection Advice: The appropriate cooling method depends on capacity, duty cycle, environment, installation conditions, and project requirements.
Delivering long-term equipment protection, energy efficiency, and high operational uptime.
Continuously compensates for input-voltage variations within its specified correction range, eliminating manual adjustments.
20 kVA provides substantial capacity to safeguard multiple CNC machines, main factory sections, or entire commercial floors.
Transformer oil assists both thermal management and dielectric insulation, allowing heavy duty operation under high ambient temperatures.
Maintains a strictly regulated ±1% voltage waveform, protecting sensitive microcontrollers, CNC encoders, and power supplies.
Input range, output setpoint, copper windings, protection trip points, monitoring, and bypass switchgear are customized to your project.
Eliminates premature component burnouts, nuisance tripping, and production losses caused by sustained high or low line voltages.
When a stabilizer supplies motors, compressors, pumps, or other high-inrush equipment, the steady-state running load alone should not be used for sizing.
Important factors to evaluate before finalizing capacity:
Use our interactive Stabilizer Capacity & Inrush Calculator or consult directly with Voltkon's senior electrical engineering team.
Calculate Your Capacity ⚡Direct Factory Engineering Support:
Follow these 8 engineering steps before issuing your final purchase specification:
Select your exact load capacity to view technical specifications, circuit topologies, and current ratings.
Detailed engineering answers regarding the 20 kVA Air Cooled Servo Stabilizer.
It is an automatic voltage regulation system rated at 20 kVA that uses servo-controlled voltage correction and an oil-cooled transformer assembly for industrial and commercial applications requiring continuous thermal management and high uptime.
Yes. Three-phase configurations (415V nominal, with independent phase-sensing and motorized adjustment) are standard for industrial power systems, and custom single-phase builds are also available.
At 400 V three-phase, 20 kVA corresponds to approximately 28.8 A of apparent-power current ($60,000 / (1.732 imes 400)$), and at 415 V three-phase it delivers approximately 83.5 A per phase. Actual permissible loading depends on power factor, starting inrush, and stabilizer design.
Yes. The input correction window can be engineered according to actual site measurements, including Standard (340V-470V), Wide (300V-480V), or Ultra-Wide (250V-480V) configurations.
Yes, subject to appropriate sizing. Motor starting current (typically 5x to 7x rated running current for DOL starters) and simultaneous starting conditions should be considered rather than sizing solely from running kVA.
No. A servo stabilizer regulates voltage but does not provide battery backup. An online UPS is required when uninterrupted power is needed during total mains failure.
Yes. A manual rotary bypass or automatic bypass arrangement can be incorporated according to the electrical system and project requirements for easy servicing.
Yes. Voltkon manufactures stabilizers with 100% electrolytic copper windings for maximum electrical conductivity, minimal thermal losses, and extended service life.
Yes. Oil-filled equipment requires periodic inspection, including checking oil level via the sight gauge, monitoring oil dielectric breakdown voltage (BDV), inspecting breather silica gel, and checking terminal tightness.
Higher-capacity oil-cooled voltage regulation up to 139 A per phase for heavy manufacturing plants and CNC machine lines.
Heavy central substation power stabilizer for entire industrial plants, processing units, and multi-machine factories.
Complete galvanic isolation and harmonic noise suppression to decouple sensitive PLC and drive controls from the raw grid.
In-depth technical papers and sizing methodologies by Voltkon engineers to help you select, operate, and maintain your power equipment.
Formulas, motor starting inrush multipliers, and power factor correction tables for factory equipment.
Thermal dissipation analysis, footprint differences, dust tolerance, and cost-benefit breakdown.
Carbon brush inspection, transformer oil BDV testing, micro-switch servicing, and life extension tips.
Comprehensive pricing for 5 kVA to 500 kVA air-cooled and oil-cooled models with factory warranty.

Custom capacity sizing, 1 kVA - 2000 kVA stabilizers & transformers engineered for your exact voltage load.